Introducing a NEW Standard in Moisture Analysis!
| Featuring These Great Additions Over Previous Models: |
 |
No toxic reagents or specialized glassware |
 |
Portable |
 |
Automatic, menu-driven operation requires minimal user skills |
 |
Automatic sample loading |
 |
Accepts smaller sample sizes, down to 10 milligrams |
 |
Greater detection range, down to 10 ppm or 10 micrograms of water |
 |
Greater temperature range, programmable start and test temperatures from 25- 275 °C |
 |
Moisture specific sensor, eliminates volatile interferences associated with LOD technology |
 |
Self-diagnostics alert operator of any instrument problems |
 |
Security feature restricts access to program and instrument settings |
| Vapor Pro Specifications: |
| Sample Size |
10 mg to 20 g |
| Resolution |
1 ppm |
| Moisture Range |
10 ppm (or 10 micrograms water) to 100% |
| Results Display |
% Moisture, ppm Moisture, or micrograms Water |
| Ending Criteria |
Predict, Rate, and Time |
| Heating Range |
25 - 275 °C, Set in 1 °C increments and maintained to ± 1 °C |
| Test Parameter Memory |
102 Programs |
| Program Identification |
Alphanumeric and/or symbols; programmable prompts for lot or product ID numbers |
| Test Result Memory |
Data from last 30 tests |
| Statistical Calculation |
Mean, Standard Deviation, and Coefficient of Variation |
| Power Requirements |
100-120V ~ 50/60 Hz, 1 amp (standby) or 8 amps (heat on),
or 220-240V ~ 50/60 Hz, 0.5 amp (standby) or 4 amps (heat on) |
| Interfaces |
RS-232 (9-pin standard); parallel printer (LPT - PC standard); 5 pin DIN connector for 101 key PC keyboard |
| Dimensions |
146mm H x 380mm W x 370mm D; 5.75" H x 15" W x 14.5" D |
| Weight |
8.6 kg; 19 pounds |
| Warranty |
Two years, factory parts and labor (one year international) |
| Certifications |
U.S. and Canadian Underwriters Laboratory; European Communities - CE |
| Accessories |
Keyboard; Printer; Analytical Balance; Carrying Case; Compressed Air Pump; Temperature Calibration Module |
| Additional Features: |
 |
Easy setup of product methods to ensure optimum test results |
 |
Starting temperatures are programmable and maintained within ± 1 °C |
 |
Continuous display of test time, current temperature, programmed test temperature, current microgram water measurement, and calculated moisture content |
 |
Flexible ending criteria to ensure accurate test results |
 |
Statistical features allow calculation of mean, standard deviation and coefficient of variation |
 |
NIST traceable multi-point temperature calibration |
Trial Instruments Available Free Application Development
24 Hour Customer Support Free Loaner Service
|
|